SNMP / Vendor profile¶
SNMP / vendor profile adds standard values or custom numeric OIDs.
Enter the target, port and SNMP credentials.
Select Vendor profile:
standard,cisco,fortigate,mikrotikorcustom.If necessary, add Additional OIDs using Add row.
Test and save.
Field per additional OID |
Meaning |
|---|---|
Label |
Measurement name |
OID |
Numeric OID, for example |
Unit, Scale factor |
Display and conversion |
Change per second |
Show the counter change per second instead of the raw counter value |
Expected value |
Optional exact value expected to be returned |
Warning at, Critical at |
Optional upper thresholds |
Tables are resolved by instance. The standard profile includes uptime; the vendor profiles offer selected typical vendor OIDs. The test must confirm whether the specific model supports them. Unsupported OIDs are explicitly shown as missing. With custom, at least one custom OID must be present. A maximum of 100 additional OID rows can be configured.